Approximate Air Coil Inductance Calculator Results

The results are valid only for one layer, tightly wound, air core coils without gaps between the turns.


   Number of coil turns : 3.0
            Coil length : 10.000 mm (0.394 inches) 
          Coil diameter : 5.000 mm (0.197 inches) 

Approximate inductance : 0.018443 µH 0.1% accurate inductance : 0.018170 µH

Methods of Increasing Inductor Q

Dimensions, Weight and Resistance of Solid Round Copper Wire

Size
AWG
Diamater (inches)
bare wire
TPI
Turns per inch
Area Circular
mils
LBS per
1000 FT
FT per
LB
OHMS PER
1000 FT
OHMS PER
pound
18
.0403
24.81389
1620
4.916
203.40
6.386
1.299
19
.0359
27.85515
1290
3.901
256.30
8.047
2.063
20
.0320
31.25000
1020
3.100
322.60
10.13
3.268
21
.0285
35.08771
812
2.459
406.70
12.77
5.193
22
.0253
39.52569
640
1.938
516.10
16.20
8.363
23
.0226
44.24778
511
1.546
646.80
20.31
1313
24
.0201
49.75124
404
1.223
817.70
25.67
20.99
25
.0179
55.86592
320
.9699
1031
32.37
33.37
26
.0159
62.89308
253
.7652
1307
41.02
53.61
27
.0142
70.42253
202
.6104
1638
51.44
84.27
28
.0126
79.36507
159
.4806
2081
65.33
135.90
29
.0113
88.49557
128
.3865
2587
81.22
210.10
30
.0100
100.0000
100
.3027
3304
103.7
342.60
31
.0089
112.3595
79.2
.2398
4171
130.90
546.1
32
.0080
125.0000
64.0
.1937
5162
162.10
836.50
33
.0071
140.8450
50.40
.5126
6553
205.70
1348
34
.0063
158.7301
39.7
.1201
8324
216.3
21.75
Resistance values based on copper of 100% conductivity at 68 deg F (20 deg C) reference: NEMA standerds MW 100, tables 1-1, 1-2 and 1-3

Calculated on Sat May 10 00:19:35 2008 GMT